Call Us: (800) 701-0186

Enbio S Fully Automatic Class B Steam Autoclave

SKU: NS-ENBIO-S Categories: ,

$4,599.99

CALL OR EMAIL FOR OUR BEST PRICE GUARANTEE  800-701-0186                 CLICK HERE TO EMAIL

2 YEAR WARRANTY &  FREE SHIPPING (Including Insurance)

enbio-distilled-water-and-waste-water-bottle-kit

Offered Exclusively from AdvanTech Sterilizers…

Free Water Bottles With Purchase

Free Loaner Service for All Warranty Repairs

In-stock Guarantee (Same Day Shipping if Ordered by 1pm PST)

 

Enbio S – Fully Automatic Class B Steam Automatic Autoclave

Exceeds all Health Canada and Provincial Infection Control Guidelines

Fast Cycles

Sterilize instruments between patients in only 7 minutes!

Capacity

Tray Size:  11 in. x 7 in. x 1.3 in          (28 cm x 18 cm x 3.5  cm)

Smaller But Better

Process more instruments in a shorter amount of time.  Holds up to 8 packs per cycle

Full Drying 

Full drying capability with
15-minute wrapped cycles.
Pouches come out bone dry!

USB Datalogger

Record cycle data on USB
Download and Store with Enbio Software

Incredibly Silent

So quiet you will barely notice the sterilizer is running.

A compact, economical option suited for a wide range of applications such as medical and dental offices, laboratories, tattoo & piercing tattoo and body-piercing studios, beauty salons, laboratories, podiatry and foot care.

  • Class B – Pre/Post Vaccum Sterilization Ensures the Highest Level of Tabletop Sterilization  (Superior to Gravity Displacement Method)
  • When using Class B/Pre-Vac sterilizers, the air is first removed from the chamber before the sterilization phase begins. This method ensures that there are no unsterilized air pockets left, making it ideal for sterilizing delicate instruments like dental handpieces. Unlike in Gravity Displacement Sterilizers, there is no need to leave space around the sterilization packs for air movement.
  • Full Automatic with Pre-set Programs: Unwrapped, Wrapped, Hollow, Liquid, Solid, Textile and Porous items
  • High-precision Temperature and Pressure Control.
  • Complies with EN13060, Health Canada and CSA Electrical Standards
  • Easy to Use and Operates Quietly.
  • Easily Accessible Water Tank.
  • Built-in Steam Generator Ensures Rapid Sterilization Cycles.
  • Vacuum-Assisted Drying Ensures Completely Dry Packs
  • Separate Fresh-Water and Waste-Water Tanks.
  • User-friendly LCD Screen Displaying Time, Temperature, Pressure, Process Alerts and Programmed Cycle.
  • Multilanguage Menu
  • Double-Safety Protection prevents a cycle from starting if the door is not correctly locked.
  • Pressure Safety Valve Prevents Overpressure in the Chamber and Steam Generator.
  • Power Automatically cuts if a short circuit or electrical fault occurs.
  • Specific Error Codes detect and identify the exact cause of any operator or technical problem. The water Level Switch controls the min/max water level.
  • Bowie Dick and Helix Testing Options Available  (Not Required)
  • Automatic Maintenance Warning.
  • 2 Year Warranty or 4000 Cycles (whichever comes first)
  • Replacement Unit within the first warranty year (click here for details)
  • Free Technical Support Hotline:  844-ENBIO-US  (362-4687)  or email: service.ca@enbio.com
  • Loaner Service Available (This is an Exclusive Bonus available only to customers that purchase from AdvanTech Sterilizers)
  • Same Day FREE Shipping with $4000.00 Insurance to most Canadian locations

 

Is a Bowie Dick test Required with the Enbio S Autoclave?

If you don’t use instruments that require processing in a Class B autoclave, then you don’t need to perform a Bowie Dick test on your Enbio S autoclave. Instead, you can carry out a daily Vacuum Test Cycle or the Helix Test Cycle from a cold start. These cycles do not need additional test packs, cards, or vials. Just push the button and wait for the cycle to complete. When done, a test report with either a Pass or Fail status will show up on the screen, and you can find more details on the test report saved on the USB drive.

Model: Enbio S
Load Space11” x 7” x 1.3”
Overall Dimensions (WxHxD)9.8” x 6.3” x 22”
Number of TraysIncludes 1 main tray (11” x 7” x 1.3”) fits a max of 8 pouches
Voltage110-120V/60Hz
Power (W)1600W, Max power consumption 15A

 

PROGRAM CYCLE

134ºC FAST

134ºC

121ºC

Type of loadUnwrapped instruments onlyWrapped or Unwrapped instrumentsWrapped or Unwrapped instruments
Process temperature

134ºC

134ºC

121ºC

Pre-vacuum number

1

3

3

Drying duration

4 min

4 min

30 min

Total process duration*100g: 7 min100g: 13 min100g: 45 min

 

PROGRAM CYCLEBowie & Dick /HelixVacuum Leak Test
Process temperature

134ºC

Pre-vacuum number

3

1

Sterilization duration

3.5 min

Drying duration

3 min

Total process duration

15 min

16 min

 

External Tank connectors

  • Enbio uses external clean and waste water drains.
  • drain tubes come with sterilizer, attach to any distilled water supply and waste water container

Chamber Size:

  • Unit Dimensions: 9.8” x 6.3” x 22”
  • Tray: 1  (holds max of 8 pouches)
  • Tray Size: 11” x 7” x 1.3”

Enbio Sales Sheet (PDF Download)

Enbio-User-manual (PDF Download)

Enbio Health Canada Licence (PDF Download)

Enbio Customer Tech Support Hotline (PDF Download)

Enbio Canada 2-Year Warranty Structure (PDF Download)

KEY FEATURES

A compact, economical option suited for a wide range of applications such as medical and dental offices, laboratories, tattoo & piercing tattoo and body-piercing studios, beauty salons, laboratories, podiatry and foot care.

  • Class B – Pre/Post Vaccum Sterilization Ensures the Highest Level of Tabletop Sterilization  (Superior to Gravity Displacement Method)
  • When using Class B/Pre-Vac sterilizers, the air is first removed from the chamber before the sterilization phase begins. This method ensures that there are no unsterilized air pockets left, making it ideal for sterilizing delicate instruments like dental handpieces. Unlike in Gravity Displacement Sterilizers, there is no need to leave space around the sterilization packs for air movement.
  • Full Automatic with Pre-set Programs: Unwrapped, Wrapped, Hollow, Liquid, Solid, Textile and Porous items
  • High-precision Temperature and Pressure Control.
  • Complies with EN13060, Health Canada and CSA Electrical Standards
  • Easy to Use and Operates Quietly.
  • Easily Accessible Water Tank.
  • Built-in Steam Generator Ensures Rapid Sterilization Cycles.
  • Vacuum-Assisted Drying Ensures Completely Dry Packs
  • Separate Fresh-Water and Waste-Water Tanks.
  • User-friendly LCD Screen Displaying Time, Temperature, Pressure, Process Alerts and Programmed Cycle.
  • Multilanguage Menu
  • Double-Safety Protection prevents a cycle from starting if the door is not correctly locked.
  • Pressure Safety Valve Prevents Overpressure in the Chamber and Steam Generator.
  • Power Automatically cuts if a short circuit or electrical fault occurs.
  • Specific Error Codes detect and identify the exact cause of any operator or technical problem. The water Level Switch controls the min/max water level.
  • Bowie Dick and Helix Testing Options Available  (Not Required)
  • Automatic Maintenance Warning.
  • 2 Year Warranty or 4000 Cycles (whichever comes first)
  • Replacement Unit within the first warranty year (click here for details)
  • Free Technical Support Hotline:  844-ENBIO-US  (362-4687)  or email: service.ca@enbio.com
  • Loaner Service Available (This is an Exclusive Bonus available only to customers that purchase from AdvanTech Sterilizers)
  • Same Day FREE Shipping with $4000.00 Insurance to most Canadian locations

 

Is a Bowie Dick test Required with the Enbio S Autoclave?

If you don’t use instruments that require processing in a Class B autoclave, then you don’t need to perform a Bowie Dick test on your Enbio S autoclave. Instead, you can carry out a daily Vacuum Test Cycle or the Helix Test Cycle from a cold start. These cycles do not need additional test packs, cards, or vials. Just push the button and wait for the cycle to complete. When done, a test report with either a Pass or Fail status will show up on the screen, and you can find more details on the test report saved on the USB drive.

SPECIFICATIONS
Model: Enbio S
Load Space11” x 7” x 1.3”
Overall Dimensions (WxHxD)9.8” x 6.3” x 22”
Number of TraysIncludes 1 main tray (11” x 7” x 1.3”) fits a max of 8 pouches
Voltage110-120V/60Hz
Power (W)1600W, Max power consumption 15A

 

PROGRAM CYCLE

134ºC FAST

134ºC

121ºC

Type of loadUnwrapped instruments onlyWrapped or Unwrapped instrumentsWrapped or Unwrapped instruments
Process temperature

134ºC

134ºC

121ºC

Pre-vacuum number

1

3

3

Drying duration

4 min

4 min

30 min

Total process duration*100g: 7 min100g: 13 min100g: 45 min

 

PROGRAM CYCLEBowie & Dick /HelixVacuum Leak Test
Process temperature

134ºC

Pre-vacuum number

3

1

Sterilization duration

3.5 min

Drying duration

3 min

Total process duration

15 min

16 min

 

External Tank connectors

  • Enbio uses external clean and waste water drains.
  • drain tubes come with sterilizer, attach to any distilled water supply and waste water container

Chamber Size:

  • Unit Dimensions: 9.8” x 6.3” x 22”
  • Tray: 1  (holds max of 8 pouches)
  • Tray Size: 11” x 7” x 1.3”
DOCUMENTATION

Enbio Sales Sheet (PDF Download)

Enbio-User-manual (PDF Download)

Enbio Health Canada Licence (PDF Download)

Enbio Customer Tech Support Hotline (PDF Download)

Enbio Canada 2-Year Warranty Structure (PDF Download)

Recordkeeping:

  • USB port:  A thumb drive is provided for easy documentation upload for digital cycle data storage.
  • Internal Memory:  The last 20 cycles are automatically stored in the autoclave and can be printed out at any time
  • Enbio software program:  Easily organize, view, store and make notes about cycle.
Enbio-software

Compare the Enbio S with the Statim 2000

Select:

Enbio S Only, Enbio S and SteriCheck Spore Testing Kit, Enbio S and MiniBio Spore Testing Kit

SKUNS-ENBIO-S

Brand

Enbio

0
CART
  • No products in the cart.